VFD185C23A-21 - 18.5 kW/25 Hp, 75 Ampere, 3 Phase 230V, IP20/UL Open Type, Inverter – Ac Motor Drive

0 out of 5

Capacity: 18.5 kW/25 Hp Voltage: 3 Phase 230V Rated Output Current: 75 Amp Max. Output Frequency: 0.00 ~599.00 Hz Control Mode: 230VAC / 460VAC models: Available modes below via parameter settings • IMVF (Induction Motor V/F control) • IMVF + PG (Induction Motor, V/F control with encoder) • IM/PM SVC (Inductor Motor / Permanent-magnet Synchronous Motor, space vector control) • IMFOC + PG (Induction Motor, field-oriented control with encoder) • PMFOC + PG (Permanent-magnet Synchronous Motor, field-oriented control with encoder) • IMFOC Sensorless (Induction Motor, sensorless field-oriented control) • PM Sensorless (Permanent-magnet Synchronous Motor, sensorless field-oriented control) • IPM Sensorless (Interior Permanent Synchronous Motor, sensorless vector control) • SynRM Sensorless (Synchronous Reluctance Motor, sensorless field-oriented control) • IM TQCPG (Induction Motor, torque control with encorder) • PM TQCPG (Permanent-magnet Synchronous Motor, torque control with encoder) • IM TQC Sensorless (Induction Motor, sensorless torque control) • SynRM TQC Sensorless (Synchronous Reluctance Motor, sensorless torque control) Dual rating design: -Heavy Duty (HD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 180% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. -Super Heavy Duty (SHD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 200% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. Starting Torque: • IMVF, IMVF+PG, IMSVC: 150% / 3 Hz • IMFOC Sensorless: 200% / 0.5 Hz • IMFOC + PG: 200% / 0 Hz • PMSVC: 100% / (motor rated frequency / 20) • PM Sensorless: 100% / (motor rated frequency / 50) • IPM Sensorless: 100% / 0 Hz • PMFOC + PG: 200% / 0 Hz Supports high speed pulse and PWM signal input Frequency Setting Signal: 0 ~ 10V / -10~+10V / 4(0) 20mA, Pulse Input (10kHz) Built-in braking choppers for the entire series Series: C2000/C2000 Plus

Read more

VFD185C43A-21 - 18.5 kW/25 Hp, 38 Ampere, 3 Phase 460V, IP20/UL Open Type, Inverter – Ac Motor Drive

0 out of 5

Capacity: 18.5 kW/25 Hp Voltage: 3 Phase 460V Rated Output Current: 38 Amp Max. Output Frequency: 0.00 ~599.00 Hz Control Mode: 230VAC / 460VAC models: Available modes below via parameter settings • IMVF (Induction Motor V/F control) • IMVF + PG (Induction Motor, V/F control with encoder) • IM/PM SVC (Inductor Motor / Permanent-magnet Synchronous Motor, space vector control) • IMFOC + PG (Induction Motor, field-oriented control with encoder) • PMFOC + PG (Permanent-magnet Synchronous Motor, field-oriented control with encoder) • IMFOC Sensorless (Induction Motor, sensorless field-oriented control) • PM Sensorless (Permanent-magnet Synchronous Motor, sensorless field-oriented control) • IPM Sensorless (Interior Permanent Synchronous Motor, sensorless vector control) • SynRM Sensorless (Synchronous Reluctance Motor, sensorless field-oriented control) • IM TQCPG (Induction Motor, torque control with encorder) • PM TQCPG (Permanent-magnet Synchronous Motor, torque control with encoder) • IM TQC Sensorless (Induction Motor, sensorless torque control) • SynRM TQC Sensorless (Synchronous Reluctance Motor, sensorless torque control) Dual rating design: -Heavy Duty (HD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 180% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. -Super Heavy Duty (SHD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 200% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. Starting Torque: • IMVF, IMVF+PG, IMSVC: 150% / 3 Hz • IMFOC Sensorless: 200% / 0.5 Hz • IMFOC + PG: 200% / 0 Hz • PMSVC: 100% / (motor rated frequency / 20) • PM Sensorless: 100% / (motor rated frequency / 50) • IPM Sensorless: 100% / 0 Hz • PMFOC + PG: 200% / 0 Hz Supports high speed pulse and PWM signal input Frequency Setting Signal: 0 ~ 10V / -10~+10V / 4(0) 20mA, Pulse Input (10kHz) Built-in braking choppers for the entire series Series: C2000/C2000 Plus

Read more

VFD2200C43A-00 - 220 kW/300 Hp, 460 Ampere, 3 Phase 460V, IP20/UL Open Type, Inverter – Ac Motor Drive

0 out of 5

Capacity: 220 kW/300 Hp Voltage: 3 Phase 460V Rated Output Current: 460 Amp Max. Output Frequency: 0.00 ~599.00 Hz Control Mode: 230VAC / 460VAC models: Available modes below via parameter settings • IMVF (Induction Motor V/F control) • IMVF + PG (Induction Motor, V/F control with encoder) • IM/PM SVC (Inductor Motor / Permanent-magnet Synchronous Motor, space vector control) • IMFOC + PG (Induction Motor, field-oriented control with encoder) • PMFOC + PG (Permanent-magnet Synchronous Motor, field-oriented control with encoder) • IMFOC Sensorless (Induction Motor, sensorless field-oriented control) • PM Sensorless (Permanent-magnet Synchronous Motor, sensorless field-oriented control) • IPM Sensorless (Interior Permanent Synchronous Motor, sensorless vector control) • SynRM Sensorless (Synchronous Reluctance Motor, sensorless field-oriented control) • IM TQCPG (Induction Motor, torque control with encorder) • PM TQCPG (Permanent-magnet Synchronous Motor, torque control with encoder) • IM TQC Sensorless (Induction Motor, sensorless torque control) • SynRM TQC Sensorless (Synchronous Reluctance Motor, sensorless torque control) Dual rating design: -Heavy Duty (HD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 180% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. -Super Heavy Duty (SHD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 200% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. Starting Torque: • IMVF, IMVF+PG, IMSVC: 150% / 3 Hz • IMFOC Sensorless: 200% / 0.5 Hz • IMFOC + PG: 200% / 0 Hz • PMSVC: 100% / (motor rated frequency / 20) • PM Sensorless: 100% / (motor rated frequency / 50) • IPM Sensorless: 100% / 0 Hz • PMFOC + PG: 200% / 0 Hz Supports high speed pulse and PWM signal input Frequency Setting Signal: 0 ~ 10V / -10~+10V / 4(0) 20mA, Pulse Input (10kHz) Built-in braking choppers for the entire series Series: C2000/C2000 Plus

Read more

VFD220C23A-21 - 22 kW/30 Hp, 90 Ampere, 3 Phase 230V, IP20/UL Open Type, Inverter – Ac Motor Drive

0 out of 5

Capacity: 22 kW/30 Hp Voltage: 3 Phase 230V Rated Output Current: 90 Amp Max. Output Frequency: 0.00 ~599.00 Hz Control Mode: 230VAC / 460VAC models: Available modes below via parameter settings • IMVF (Induction Motor V/F control) • IMVF + PG (Induction Motor, V/F control with encoder) • IM/PM SVC (Inductor Motor / Permanent-magnet Synchronous Motor, space vector control) • IMFOC + PG (Induction Motor, field-oriented control with encoder) • PMFOC + PG (Permanent-magnet Synchronous Motor, field-oriented control with encoder) • IMFOC Sensorless (Induction Motor, sensorless field-oriented control) • PM Sensorless (Permanent-magnet Synchronous Motor, sensorless field-oriented control) • IPM Sensorless (Interior Permanent Synchronous Motor, sensorless vector control) • SynRM Sensorless (Synchronous Reluctance Motor, sensorless field-oriented control) • IM TQCPG (Induction Motor, torque control with encorder) • PM TQCPG (Permanent-magnet Synchronous Motor, torque control with encoder) • IM TQC Sensorless (Induction Motor, sensorless torque control) • SynRM TQC Sensorless (Synchronous Reluctance Motor, sensorless torque control) Dual rating design: -Heavy Duty (HD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 180% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. -Super Heavy Duty (SHD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 200% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. Starting Torque: • IMVF, IMVF+PG, IMSVC: 150% / 3 Hz • IMFOC Sensorless: 200% / 0.5 Hz • IMFOC + PG: 200% / 0 Hz • PMSVC: 100% / (motor rated frequency / 20) • PM Sensorless: 100% / (motor rated frequency / 50) • IPM Sensorless: 100% / 0 Hz • PMFOC + PG: 200% / 0 Hz Supports high speed pulse and PWM signal input Frequency Setting Signal: 0 ~ 10V / -10~+10V / 4(0) 20mA, Pulse Input (10kHz) Built-in braking choppers for the entire series Series: C2000/C2000 Plus

Read more

VFD220C43A-21 - 22 kW/30 Hp, 45 Ampere, 3 Phase 460V, IP20/UL Open Type, Inverter – Ac Motor Drive

0 out of 5

Capacity: 22 kW/30 Hp Voltage: 3 Phase 460V Rated Output Current: 45 Amp Max. Output Frequency: 0.00 ~599.00 Hz Control Mode: 230VAC / 460VAC models: Available modes below via parameter settings • IMVF (Induction Motor V/F control) • IMVF + PG (Induction Motor, V/F control with encoder) • IM/PM SVC (Inductor Motor / Permanent-magnet Synchronous Motor, space vector control) • IMFOC + PG (Induction Motor, field-oriented control with encoder) • PMFOC + PG (Permanent-magnet Synchronous Motor, field-oriented control with encoder) • IMFOC Sensorless (Induction Motor, sensorless field-oriented control) • PM Sensorless (Permanent-magnet Synchronous Motor, sensorless field-oriented control) • IPM Sensorless (Interior Permanent Synchronous Motor, sensorless vector control) • SynRM Sensorless (Synchronous Reluctance Motor, sensorless field-oriented control) • IM TQCPG (Induction Motor, torque control with encorder) • PM TQCPG (Permanent-magnet Synchronous Motor, torque control with encoder) • IM TQC Sensorless (Induction Motor, sensorless torque control) • SynRM TQC Sensorless (Synchronous Reluctance Motor, sensorless torque control) Dual rating design: -Heavy Duty (HD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 180% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. -Super Heavy Duty (SHD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 200% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. Starting Torque: • IMVF, IMVF+PG, IMSVC: 150% / 3 Hz • IMFOC Sensorless: 200% / 0.5 Hz • IMFOC + PG: 200% / 0 Hz • PMSVC: 100% / (motor rated frequency / 20) • PM Sensorless: 100% / (motor rated frequency / 50) • IPM Sensorless: 100% / 0 Hz • PMFOC + PG: 200% / 0 Hz Supports high speed pulse and PWM signal input Frequency Setting Signal: 0 ~ 10V / -10~+10V / 4(0) 20mA, Pulse Input (10kHz) Built-in braking choppers for the entire series Series: C2000/C2000 Plus

Read more

VFD25AME23ANNAA - 5.5 kW/7.5 Hp, 25 Ampere, 3 Phase 230V, IP20 Standard, Inverter - Ac Motor Drive

0 out of 5

Capacity: 5.5 kW/7.5 Hp Voltage: 3 Phase 230V Rated Output Current: 25.0 Amp Max. Output Frequency: 0.00 ~599.00 Hz (±0.1%) Control Mode: V/F, SVC Applicant Motor: Induction motor (IM), interior permanent magnet (IPM) motor, surface permanent magnet (SPM) motor Dual rating design: -Normal Duty (ND), 120% for 60 seconds or 150% for 3 seconds -Heavy Duty (HD), 150% for 60 seconds or 200% for 3 seconds Up to 200% rated starting torque at 3 Hz Supports high speed pulse and PWM signal input Frequency Setting Signal: 0 ~ 10V / 4(0) 20mA, 1 pulse input (10kHz) Built-in single /multi-pump function Built-in braking choppers for the entire series ANNAA: Standard Drive Series: ME300

Read more

VFD25AMS23ANSAA - 5.5 kW/7.5 Hp, 25.0 Ampere, 3 Phase 230V, IP20 Standard, Inverter - Ac Motor Drive

0 out of 5

Capacity: 5.5 kW/7.5 Hp Voltage: 3 Phase 230V Rated Output Current: 25.0 Amp Control Mode: V/F, SVC, FOC Sensorless Applicant Motor: Induction motors (IM), interior permanent magnet (IPM) motors, and surface permanent magnet (SPM) motors Standard Model Max. Output Frequency: 0.00 ~599.00 Hz (±0.1%) High speed model: 1500.0 Hz (with derating, V/F control only) Dual rating design: -Normal Duty (ND): 120% of rated output current for 60 seconds; 150% of rated output current for 3 seconds -Heavy Duty (HD): 150% of rated output current for 60 seconds; 200% of rated output current for 3 seconds Up to 200% rated starting torque at 3 Hz Frequency Setting Signal: 0 ~ +10 V / -10 V ~ +10 V, 4 ~ 20 mA / 0 ~ +10 V, 1 pulse input (33 kHz), 1 pulse output (33 kHz) Multi-motor Control,built-in four IM motor control parameters Built-in PLC program with 2K steps capacity Built-in brake choppers for the entire series Safety standard compliance: Safe Torque Off (SIL2/PLd) ANSAA: Standard Drive Series: MS300

Read more

VFD25AMS43ANSAA - 11 kW/15 Hp, 25 Ampere, 3 Phase 460V, IP20 Standard, Inverter - Ac Motor Drive

0 out of 5

Capacity: 11 kW/15 Hp Voltage: 3 Phase 460V Rated Output Current: 25 Amp Control Mode: V/F, SVC, FOC Sensorless Applicant Motor: Induction motors (IM), interior permanent magnet (IPM) motors, and surface permanent magnet (SPM) motors Standard Model Max. Output Frequency: 0.00 ~599.00 Hz (±0.1%) High speed model: 1500.0 Hz (with derating, V/F control only) Dual rating design: -Normal Duty (ND): 120% of rated output current for 60 seconds; 150% of rated output current for 3 seconds -Heavy Duty (HD): 150% of rated output current for 60 seconds; 200% of rated output current for 3 seconds Up to 200% rated starting torque at 3 Hz Frequency Setting Signal: 0 ~ +10 V / -10 V ~ +10 V, 4 ~ 20 mA / 0 ~ +10 V, 1 pulse input (33 kHz), 1 pulse output (33 kHz) Multi-motor Control,built-in four IM motor control parameters Built-in PLC program with 2K steps capacity Built-in brake choppers for the entire series Safety standard compliance: Safe Torque Off (SIL2/PLd) ANSAA: Standard Drive Series: MS300

Read more

VFD25AMS43ENSAA - 11 kW/15 Hp, 25.0 Ampere, 3 Phase 460V, IP20 Standard, Inverter - Ac Motor Drive

0 out of 5

Capacity: 11 kW/15 Hp Voltage: 3 Phase 460V Rated Output Current: 25.0 Amp Standard Model Max. Output Frequency: 0.00 ~599.00 Hz (±0.1%) High speed model: 1500.0 Hz (with derating, V/F control only) Dual rating design: -Normal Duty (ND): 120% of rated output current for 60 seconds; 150% of rated output current for 3 seconds -Heavy Duty (HD): 150% of rated output current for 60 seconds; 200% of rated output current for 3 seconds Up to 200% rated starting torque at 3 Hz Frequency Setting Signal: 0 ~ +10 V / -10 V ~ +10 V, 4 ~ 20 mA / 0 ~ +10 V, 1 pulse input (33 kHz), 1 pulse output (33 kHz) Multi-motor Control,built-in four IM motor control parameters Built-in PLC program with 2K steps capacity Built-in brake choppers for the entire series Safety standard compliance: Safe Torque Off (SIL2/PLd) Series: MS300

Read more

VFD2800C43A-00 - 280 kW/375 Hp, 550 Ampere, 3 Phase 460V, IP20/UL Open Type, Inverter – Ac Motor Drive

0 out of 5

Capacity: 280 kW/375 Hp Voltage: 3 Phase 460V Rated Output Current: 550 Amp Max. Output Frequency: 0.00 ~599.00 Hz Control Mode: 230VAC / 460VAC models: Available modes below via parameter settings • IMVF (Induction Motor V/F control) • IMVF + PG (Induction Motor, V/F control with encoder) • IM/PM SVC (Inductor Motor / Permanent-magnet Synchronous Motor, space vector control) • IMFOC + PG (Induction Motor, field-oriented control with encoder) • PMFOC + PG (Permanent-magnet Synchronous Motor, field-oriented control with encoder) • IMFOC Sensorless (Induction Motor, sensorless field-oriented control) • PM Sensorless (Permanent-magnet Synchronous Motor, sensorless field-oriented control) • IPM Sensorless (Interior Permanent Synchronous Motor, sensorless vector control) • SynRM Sensorless (Synchronous Reluctance Motor, sensorless field-oriented control) • IM TQCPG (Induction Motor, torque control with encorder) • PM TQCPG (Permanent-magnet Synchronous Motor, torque control with encoder) • IM TQC Sensorless (Induction Motor, sensorless torque control) • SynRM TQC Sensorless (Synchronous Reluctance Motor, sensorless torque control) Dual rating design: -Heavy Duty (HD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 180% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. -Super Heavy Duty (SHD), At 150% of the rated output current, continuous operation lasts up to 1 min. in every 5 mins. At 200% of the rated output current, continuous operation lasts up to 3 secs. in every 30 secs. Starting Torque: • IMVF, IMVF+PG, IMSVC: 150% / 3 Hz • IMFOC Sensorless: 200% / 0.5 Hz • IMFOC + PG: 200% / 0 Hz • PMSVC: 100% / (motor rated frequency / 20) • PM Sensorless: 100% / (motor rated frequency / 50) • IPM Sensorless: 100% / 0 Hz • PMFOC + PG: 200% / 0 Hz Supports high speed pulse and PWM signal input Frequency Setting Signal: 0 ~ 10V / -10~+10V / 4(0) 20mA, Pulse Input (10kHz) Built-in braking choppers for the entire series Series: C2000/C2000 Plus

Read more

VFD2A7ME43AFNAA - 0.75 kW/1 Hp, 2.7 Ampere, 3 Phase 460V, IP20 Standard, Inverter - Ac Motor Drive

0 out of 5

Capacity: 0.75 kW/ Hp Voltage: 3 Phase 460V Rated Output Current: 2.7 Amp Max. Output Frequency: 0.00 ~599.00 Hz (±0.1%) Control Mode: V/F, SVC Applicant Motor: Induction motor (IM), interior permanent magnet (IPM) motor, surface permanent magnet (SPM) motor Dual rating design: -Normal Duty (ND), 120% for 60 seconds or 150% for 3 seconds -Heavy Duty (HD), 150% for 60 seconds or 200% for 3 seconds Up to 200% rated starting torque at 3 Hz Supports high speed pulse and PWM signal input Frequency Setting Signal: 0 ~ 10V / 4(0) 20mA, 1 pulse input (10kHz) Built-in single /multi-pump function Built-in braking choppers for the entire series AFNAA: Built-in EMC Filter Series: ME300

Read more

VFD2A7ME43ANNAA - 0.75 kW/1 Hp, 2.7 Ampere, 3 Phase 460V, IP20 Standard, Inverter - Ac Motor Drive

0 out of 5

Capacity: 0.75 kW/1 Hp Voltage: 3 Phase 460V Rated Output Current: 2.7 Amp Max. Output Frequency: 0.00 ~599.00 Hz (±0.1%) Control Mode: V/F, SVC Applicant Motor: Induction motor (IM), interior permanent magnet (IPM) motor, surface permanent magnet (SPM) motor Dual rating design: -Normal Duty (ND), 120% for 60 seconds or 150% for 3 seconds -Heavy Duty (HD), 150% for 60 seconds or 200% for 3 seconds Up to 200% rated starting torque at 3 Hz Supports high speed pulse and PWM signal input Frequency Setting Signal: 0 ~ 10V / 4(0) 20mA, 1 pulse input (10kHz) Built-in single /multi-pump function Built-in braking choppers for the entire series ANNAA: Standard Drive Series: ME300

Read more